S5720-52P-LI-AC
Version Mapping
Table 4-255 lists the mapping between the S5720-52P-LI-AC chassis and software versions.
Appearance and Structure
Port Description
10/100/1000BASE-T port
1000BASE-X port
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5720-52P-LI-AC has similar indicators to those of the S5720-28X-PWR-LI-AC, except that the S5720-52P-LI-AC does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The S5720-52P-LI-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5720-52P-LI-AC has a built-in fan for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-260 lists technical specifications of the S5720-52P-LI-AC.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
41 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
4.4 kg (9.7 lb) |
Stack ports |
Forty-eight 10/100/1000BASE-T ports and four 1000BASE-X ports |
RTC |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, full speed of fans) |
50.3 W |
Typical power consumption (30% of traffic load)
|
31.6 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 44.5 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010774 |