S5720-50X-EI-AC
Version Mapping
Table 4-910 lists the mapping between the S5720-50X-EI-AC chassis and software versions.
Appearance and Structure
1 |
One console port NOTE:
It is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed. |
2 |
One USB port |
3 |
Forty-six 10/100/1000BASE-T ports |
4 |
Four 10GE SFP+ ports Applicable modules and cables:
|
5 |
AC socket NOTE:
It is used with an AC power cable. |
6 |
Ground screw NOTE:
It is used with a ground cable. |
7 |
Two QSFP+ stack optical ports Applicable modules and cables:
|
8 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
Port Description
10/100/1000BASE-T port
10GE SFP+ port
QSFP+ stack optical port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
No. |
Indicator/Button |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or temperature alarm has been generated. |
|||
2 |
- |
USB-based deployment indicator |
- |
Off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from the USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
|||
3 |
- |
Service port indicator (one indicator for each port) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
The port is connected. |
|||
Green |
Blinking |
The port is sending or receiving data. |
|||
4 |
- |
Service port indicator (two indicators for each port) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
The port is connected. |
|||
Yellow |
Blinking |
The port is sending or receiving data. |
Power Supply Configuration
The S5720-50X-EI-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5720-50X-EI-AC has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-916 lists technical specifications of the S5720-50X-EI-AC.
Item |
Description |
---|---|
Memory (RAM) |
2 GB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
74.31 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±6 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
4.9 kg (10.81 lb) |
Stack ports |
|
RTC |
Supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, full speed of fans) |
55.3 W |
Typical power consumption (30% of traffic load)
|
47.45 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 49.3 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02359592 |