S5720-56C-EI-AC
Version Mapping
Table 4-818 lists the mapping between the S5720-56C-EI-AC chassis and software versions.
Appearance and Structure
1 |
Forty-eight 10/100/1000BASE-T ports |
2 |
Four 10GE SFP+ ports Applicable modules and cables:
|
3 |
One ETH management port |
4 |
One mini USB port |
5 |
One console port NOTE:
It is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed. |
6 |
One USB port |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
ESN label NOTE:
You can draw it out to view the ESN and MAC address of the switch. |
9 |
Rear card slot |
10 |
Fan slot NOTE:
Applicable fan module: FAN-028A-B Fan Module |
11 |
Power module slot 2 NOTE:
Applicable power modules:
|
12 |
Power module slot 1 NOTE:
Applicable power modules:
|
Port Description
10/100/1000BASE-T port
10GE SFP+ port
Console port
Mini USB port
The mini USB port is connected to a console for on-site configuration. When both the Mini USB and console port have a cable connected, only the Mini USB port works.
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5720-56C-EI-AC has similar indicators to those on the S5720-36C-PWR-EI-AC, except that the S5720-56C-EI-AC does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The S5720-56C-EI-AC uses pluggable power modules. It can be configured with a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S5720-56C-EI-AC uses pluggable fan modules for forced air cooling. Air flows in from the left and right sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-823 lists technical specifications of the S5720-56C-EI-AC.
Item |
Description |
---|---|
Memory (RAM) |
2 GB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
71.18 years when no card is configured; 66.07 years when a 2-port 10GE SFP+ interface card is configured; 66.40 years when a 2-port 10GE RJ45 interface card is configured; 64.53 years when a stack card is configured |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
|
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (with packaging) |
10 kg (22.05 lb) |
Stack ports |
|
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
86.9 W |
Typical power consumption (30% of traffic load)
|
|
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 51.2 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
02359504 |