S5720-52X-LI-DC
Version Mapping
Table 4-321 lists the mapping between the S5720-52X-LI-DC chassis and software versions.
Appearance and Structure
| 1 | Forty-eight 10/100/1000BASE-T ports | 2 | Four 10GE SFP+ ports Applicable modules and cables: 
  NOTE:  If a port uses a GPON optical module, other 10GE SFP+ optical ports cannot be used. | 
| 3 | One PNP button  NOTICE:  Applicable in V200R012C00 and later versions: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. | 4 | One console port | 
| 5 | One USB port | 6 | Ground screw  NOTE:  It is used with a ground cable. | 
| 7 | RPS socket  NOTE:  It is used with an RPS cable, which is not hot swappable. | 8 | DC power terminal  NOTE:  It is used together with a DC Power Cable. | 
Port Description
10/100/1000BASE-T port
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5720-52X-LI-DC has similar indicators to those of the S5720-28X-PWR-LI-AC, except that the S5720-52X-LI-DC does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The S5720-52X-LI-DC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5720-52X-LI-DC has a built-in fan for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-325 lists technical specifications of the S5720-52X-LI-DC.
| Item | Description | 
|---|---|
| Memory (RAM) | 512 MB | 
| Flash | 512 MB in total. To view the available flash memory size, run the display version command. | 
| Mean time between failures (MTBF) | 41 years | 
| Mean time to repair (MTTR) | 2 hours | 
| Availability | > 0.99999 | 
| Service port surge protection | Common mode: ±7 kV | 
| Power supply surge protection | ±1 kV in differential mode, ±2 kV in common mode | 
| Dimensions (H x W x D) | 
 | 
| Weight (with packaging) | 4.4 kg (9.7 lb) | 
| Stack ports | Forty-eight 10/100/1000BASE-T ports and four 10G SFP+ ports | 
| RTC | Not supported | 
| RPS | Supported | 
| PoE | Not supported | 
| Rated voltage range | -48 V DC to -60 V DC | 
| Maximum voltage range | -36 V DC to -72 V DC | 
| Maximum power consumption (100% throughput, full speed of fans) | 51.6 W | 
| Typical power consumption (30% of traffic load) 
 | 33.1 W | 
| Operating temperature | 0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)  NOTE:  When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). | 
| Short-term operating temperature | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)  NOTE:  When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: 
 The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. | 
| Storage temperature | -40°C to +70°C (-40°F to +158°F) | 
| Noise under normal temperature (27°C, sound power) | < 44.5 dB(A) | 
| Relative humidity | 5% to 95%, noncondensing | 
| Operating altitude | 0-5000 m (0-16404 ft.) | 
| Certification | 
 | 
| Part number | 98010607 | 
 
             
                         
                