S5720-52X-LI-DC
Version Mapping
Table 4-321 lists the mapping between the S5720-52X-LI-DC chassis and software versions.
Appearance and Structure
1 |
Forty-eight 10/100/1000BASE-T ports |
2 |
Four 10GE SFP+ ports Applicable modules and cables:
NOTE:
If a port uses a GPON optical module, other 10GE SFP+ optical ports cannot be used. |
3 |
One PNP button NOTICE:
Applicable in V200R012C00 and later versions: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
4 |
One console port |
5 |
One USB port |
6 |
Ground screw NOTE:
It is used with a ground cable. |
7 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
8 |
DC power terminal NOTE:
It is used together with a DC Power Cable. |
Port Description
10/100/1000BASE-T port
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5720-52X-LI-DC has similar indicators to those of the S5720-28X-PWR-LI-AC, except that the S5720-52X-LI-DC does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The S5720-52X-LI-DC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5720-52X-LI-DC has a built-in fan for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-325 lists technical specifications of the S5720-52X-LI-DC.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
41 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±1 kV in differential mode, ±2 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
4.4 kg (9.7 lb) |
Stack ports |
Forty-eight 10/100/1000BASE-T ports and four 10G SFP+ ports |
RTC |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
-48 V DC to -60 V DC |
Maximum voltage range |
-36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
51.6 W |
Typical power consumption (30% of traffic load)
|
33.1 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 44.5 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010607 |