S5720-28X-LI-24S-DC
Version Mapping
Table 4-291 lists the mapping between the S5720-28X-LI-24S-DC chassis and software versions.
Appearance and Structure
1 |
Sixteen 100/1000BASE-X ports |
2 |
Eight combo ports (10/100/1000BASE-T + 100/1000BASE-X) |
3 |
Four 10GE SFP+ ports Applicable modules and cables:
NOTE:
If a port uses a GPON optical module, other 10GE SFP+ optical ports cannot be used. |
4 |
One PNP button NOTICE:
Applicable in V200R012C00 and later versions: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
5 |
One console port |
6 |
One USB port |
7 |
DC power terminal NOTE:
It is used together with a DC Power Cable. |
8 |
Ground screw NOTE:
It is used with a ground cable. |
9 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
- |
- |
Port Description
100/1000BASE-X port
Combo port
By default, a combo port works in auto mode, in which the port type is determined as follows:
- If the optical port has no optical module installed and the electrical port has no Ethernet cable connected, the port type depends on which port is connected first. If the electrical port is connected by an Ethernet cable first, the electrical port is used for data switching. If the optical port has an optical module installed first, the optical port is used for data switching.
- If the electrical port has an Ethernet cable connected and is in Up state, the electrical port is still used for data switching when the optical port has an optical module installed.
- If the optical port, no matter in Up or Down state, has an optical module installed, the optical port is still used for data switching when the electrical port has an Ethernet cable connected.
- If the optical port has an optical module installed and the electrical port has an Ethernet cable connected, the optical port is used for data switching after the switch restarts.
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S5720-28X-LI-24S-DC has the same types of indicators as the S5720-28X-LI-24S-AC. For details, see Indicator Description.
Power Supply Configuration
The S5720-28X-LI-24S-DC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5720-28X-LI-24S-DC has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-295 lists technical specifications of the S5720-28X-LI-24S-DC.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
41 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±1 kV in differential mode, ±2 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
4.1 kg (9.04 lb) |
Stack ports |
GE SFP optical ports and 10GE SFP+ optical ports except combo ports on the front panel |
RTC |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
-48 V DC to -60 V DC |
Maximum voltage range |
-36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
42.7 W |
Typical power consumption (30% of traffic load)
|
30.3 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 43 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010631 |