Модель ASA5516-FPWR-K9 является безотказной гибкой платформой, которая эффективно организует работу сети. Отлично выполняет возрастающие потребности, позволяет снизить экономические расходы на обслуживание.
Feature |
Cisco ASA 5516-X w/ FirePOWER Services |
Maximum Throughput: Application Control (AVC) |
850 Mbps |
Maximum Throughput: Application Control (AVC) and IPS |
450 Mbps |
Sizing Throughput [440 byte HTTP]: Application Control (AVC) or IPS |
300 Mbps |
Maximum concurrent sessions |
250,000 |
Maximum New Connections per second |
20,000 |
Supported applications |
More than 3,000 |
URL categories |
80+ |
Number of URLs categorized |
More than 280 million |
Centralized configuration, logging, monitoring, and reporting |
Multi-device Cisco Security Manager (CSM) and Cisco FireSIGHT Management Center |
On-Device Management |
ASDM |
Stateful inspection throughput (maximum) |
1.8 Gbps |
Stateful inspection throughput (multiprotocol) |
900 Mbps |
Triple Data Encryption Standard/ |
250 Mbps |
Users/nodes |
Unlimited |
IPsec site-to-site VPN peers |
300 |
Cisco Cloud Web Security users |
2000 |
Cisco AnyConnect Plus/Apex VPN maximum simultaneous connections |
300 |
Virtual interfaces (VLANs) |
100 |
Security contexts5(included; maximum) |
2; 5 |
High availability |
Active/ |
USB 2.0 ports |
USB port type ‘A’, High Speed 2.0 |
Integrated I/O |
8 x 1GE |
Expansion I/O |
N/A |
Dedicated management port |
Yes (To be shared with FirePOWER Services), 10/100/1000 |
Serial ports |
1 RJ-45 and Mini USB console |
Solid-state drive |
100 GB mSata |
Memory |
8 GB |
Minimum system flash |
8GB |
System bus |
Multibus architecture |
Operating Parameters |
|
Temperature |
32 to 104°F (0 to 40 °C) |
Relative humidity |
10 to 90 percent noncondensing |
Altitude |
Designed and tested for 0 to 10,000 ft (3048 m) |
Acoustic |
41.6 dBA type |
67.2 dBA max |
|
Non-operating Parameters |
|
Temperature |
-13 to 158?F (-25 to 70?C) |
Relative humidity |
10 to 90 percent noncondensing |
Altitude |
Designed and tested for 0 to 15,000 ft (4572 m) |
Power Input (per power supply) |
|
AC range line voltage |
External, 90 to 240 volts alternating current (VAC) |
AC normal line voltage |
92 to 240 VAC |
AC current |
0.25AC amps |
AC frequency |
50/60 Hz |
Dual-power supplies |
None |
DC domestic line voltage |
N/A |
DC international line voltage |
N/A |
DC current |
N/A |
Output |
|
Steady state |
12V @ 3.0A |
Maximum |
12V @ 5.0A |
Maximum |
123 Btu/hr |
Form factor |
1 rack unit (RU), 19-in. rack-mountable |
(H x W x D) |
4.369 x 43.688 x 28.672 cm |
Weight (with AC power supply) |
3 kg |